SYNOPSIS
int modbus_read_bits(modbus_t *ctx, int addr, int nb, uint8_t *dest);
DESCRIPTION
The modbus_read_bits() function shall read the status of the nb bits (coils)
to the address addr of the remote device. The result of reading is stored in
dest array as unsigned bytes (8 bits) set to TRUE
or FALSE
.
You must take care to allocate enough memory to store the results in dest (at least nb * sizeof(uint8_t)).
The function uses the Modbus function code 0x01 (read coil status).
RETURN VALUE
The function shall return the number of read bits if successful. Otherwise it shall return -1 and set errno.
ERRORS
- EMBMDATA
-
Too many bits requested
SEE ALSO
AUTHORS
The libmodbus documentation was written by Stéphane Raimbault <[email protected]>